Fix-Thermostat FTS
Product Description
Normally open contact / NO for controlling filter fans, heat exchangers, air conditioners or for switching signal devices when temperature limit has been exceeded. The contact closes when temperature is rising.
High switching accuracy
Technical Data
- Order No.: 3150-4035-00-00
- Protection type: IP20
- Switch-off temperature: 25 °C
- Starting temperature: 35 °C
-
Operating temperature: from : -40 °C to : +80 °C
-
Storage temperature: from : -45 °C to : +80 °C
- Contact type: Snap-action contact
- Max. switching capacity: Change-over
- Max. starting current: AC 10 A for 10 Seconds
- Service lifetime: >100.000 cycles
- Sensor element: Thermoplastic
- Control system: Closed con.
- Power supply: 2-pole max. 2.5 mm², clamping screw with strain relief, max. torque 0.8Nm
- Approvals: CE; cURus
- Weight: 30 g
-
Dimensions (WxHxD): width : 93 mm height : 47 mm depth : 33 mm
- Surface finish: Plastic according to UL94 V-0, light grey
- Type: FTS35
- Fitting position: variable
Scope of Delivery
- Fix-Thermostat
Suitable for
Heat Exchangers
Air-To-Air Heat Exchangers

3114-0150-15-07
Air-To-Air Heat Exchangers
Typ | Kleinst-WT |
Nominal voltage | 230 V AC |
Approvals | CE |
Mounting type | partial mounting |

3114-0220-16-07
Air-To-Air Heat Exchangers
Typ | Mini-Mini 220 |
Nominal voltage | 230 V AC |
Approvals | CE |
Mounting type | external/internal installation |

3114-0350-25-07
Air-To-Air Heat Exchangers
Typ | Kompakt superflach 350 |
Nominal voltage | 230 V AC |
Approvals | CE |
Mounting type | external/internal installation |

3114-0500-25-07
Air-To-Air Heat Exchangers
Typ | Kompakt 500 |
Nominal voltage | 230 V AC |
Approvals | CE |
Mounting type | external/internal installation |

3114-0750-31-07
Air-To-Air Heat Exchangers
Typ | Kompakt 750 |
Nominal voltage | 230 V AC |
Approvals | CE |
Mounting type | external/internal installation |

3114-1150-25-07
Air-To-Air Heat Exchangers
Typ | Standard 1150 |
Nominal voltage | 230 V AC |
Approvals | CE |
Mounting type | external/internal installation |

3114-2000-23-07
Air-To-Air Heat Exchangers
Typ | SH2000 |
Nominal voltage | 230 V AC |
Approvals | CE |
Mounting type | external/internal installation |

3114-3250-23-07
Air-To-Air Heat Exchangers
Typ | SH3250 |
Nominal voltage | 230 V AC |
Approvals | CE |
Mounting type | external/internal installation |